N1201SA 35mhz-2700mhz Newest GSM UV Antenna Analyzer
$18.82
$27.1
N1201SA 35mhz-2700mhz Newest GSM UV Antenna Analyzer N1201SA GSM UV Antenna Analyzer Specifications Frequency 35MHz~2700MHz Spacing 1kHz Display 2.4inch TFT Pixel 320×240(QVGA) Battery 2000mAH(7.4Wh) Power dissipation <1.5W Charging current 400mA Charging port USB(For charging only) Auto Power Off Adjustable(Always on,5mins~60min) Measure facts resistance/reactance/SWR/s11 Resolution ratio 4bits effective digits Frequency accuracy ±5ppm Connector SMA-K Measuring range impedance 0.1Ω~1000Ω(Absolute value of impedance) SWR 1.000~65 s11(dB) 0dB~-60dB Error (single point measurement) impedance <Absolute value of impedance×3%±0.1Ω(Z<200Ω,<1.5GHz) SWR <Effective reading×10%±0.1> s11 (dB/°) 0.1 dB /5° (0dB~-10dB) 1 dB /10° (-10dB~-20dB) 5dB/20° (-20dB~-40dB) directivity <35dB(140MHz~2GHz After calibration) <30dB(2GHz~2.7GHz) Scan Points 280 output level -18dBm Working temperature 0~40 Atmospheric pressure 860hPa~1060hPa Dimension 120mm*86mm*30mm Description This instrument has four interfaces: single point measurement, scanning, system information, correction and calibration The default boot into single-point measurement interface. Note: For the convenience of the user, each time calibration correction options will automatically change to the user calibration. Meanwhile, in order to ensure the integrity of the calibration, the calibration process, the automatic shutdown function fails, the consistent boot. Startup and shutdown Hold down the CTRL key off press the power switch button. The boot state, long press (2S above) the switch button, after the release, the instrument will shut down The boot state, long press (2S above) the switch button, after the release, the instrument will shut down Recommend the use 1, in order to ensure the accuracy of measurement and calibration, preheat the instrument at least 15 minutes. 2, try to use good quality RF cable and connectors. 3, calibrated cable marked to the next may not need to calibrate and direct use. 4, test cable process affect the measurement accuracy, it is recommended that, where possible, do not choose too long test cable. 5, measurement and calibration before, make sure you are not in a strong wireless signal, so as to avoid interference caused by inaccurate measurements. 6, if the impedance measurements themselves do not understand, you can refer to a vector network analyzer instructions and tutorials. This instrument is equivalent to a single-port vector network analysis. Package included: 1 x N1201SA UV Antenna Analyzer (35MHz~2700MHz) 1 x USB Cable 1x English Manual If any questions Or bulk order, please contact Ms. Amy Huang: Email: [email protected] WhatsApp / Skype: 86-13860123881 Tel: 86(592)5995025 Fax: 86(592)3720556
Antenna Analyzer